The University of Texas Health Science Center at Houston Houston, TX
Andrew F. Herman, MD1, Tejal Mistry, MD1, Scott Larson, MD, PhD2, Priscila Olague, MD3 1The University of Texas Health Science Center at Houston, Houston, TX; 2University of Texas Health Science Center, Houston, TX; 3UT HSC - Houston, Houston, TX
Introduction: Colonoscopy is considered the standard for colon cancer screening. A key factor in ensuring high quality colonoscopy is adequate colon cleansing. In hospitalized patients, bowel preparation is often challenging and inadequate cleansing is often due to patient’s inability to tolerate the preparation, slow bowel transit in the setting of immobilization and acute illnesses, and the use of motility-altering medications. Poor bowel preparation limits visualization of the colonic mucosa and can lead to incomplete colonoscopies, missed pathology, adverse events, prolonged hospital stays and increased costs. New technologies have been developed to improve bowel preparations intra-procedurally. The Pure-Vu EVS system, which is an over-the-scope irrigation and cleansing device. This case report describes a novel use of the Pure-Vu EVS system to improve inpatient colonoscopy prep.
Case Description/Methods: A 58 year-old female with past medical history significant for chronic systolic heart failure, ischemic cardiomyopathy status post Left Ventricular Assist Device (LVAD) one year prior. End stage heart failure patients requiring LVAD placement routinely undergo screening colonoscopy as part of their pre-transplant evaluation, as the presence of colon cancer or advanced neoplasia could preclude heart transplantation. As part of orthotopic heart transplant evaluation she was admitted to the hospital for IV heparin bridging for screening colonoscopy. After admission, the patient was started on standard bowel prep consisting of 4L of Golytely and Dulcolax suppository. Despite completion of prep, she continued to pass sediments and prep was deemed inadequate. The patients LVAD anticoagulation had been held for the procedure and the decision was made to proceed with colonoscopy utilizing the Pure-Vu EVS device.
During the procedure the clinical team utilized the Pure-Vu EVS device and performed the procedure with cardiovascular anesthesia. The Pure-Vu EVS system effectively irrigated and suctioned areas of inadequate bowel prep with sediment larger than 3.8 mm, allowing for improved visualization of the colonic mucosa.
Discussion: Pure-Vu EVS allowed for us to perform a screening colonoscopy as part of orthotopic heart transplant evaluation in a patient with LVAD admitted a hospital inpatient service for heparin bridge. This case report describes one of the first cases of the utilization of this unique technology in a patient requiring inpatient screening colonoscopy with advanced heart failure.
Disclosures:
Andrew Herman indicated no relevant financial relationships.
Tejal Mistry indicated no relevant financial relationships.
Scott Larson: Motus GI – Consultant.
Priscila Olague indicated no relevant financial relationships.
Andrew F. Herman, MD1, Tejal Mistry, MD1, Scott Larson, MD, PhD2, Priscila Olague, MD3. C0118 - Utilizing the Pure-Vu EVS for Inpatient Colonoscopy for Patients With an LVAD: A Case Report, ACG 2022 Annual Scientific Meeting Abstracts. Charlotte, NC: American College of Gastroenterology.